Home Contact Us  

Products Enquiry >>

Free advice on detectable earplugs & detect-a-gloves
Free advice on respirators, earplugs & detectaplugs
**New** free advice on respirators

 

 

 

COMING SOON!

Exclusive to Detectamet Brand Metal Detectable FFP2 for the food industry

Fold Flats Valved

Fold Flats NONE Valved

----------------------

 

 

Free Advice  Disposable Filtering Face Piece Masks

 

C K Safety Equipment can now exclusively provide its customers in the Food /Beverage and Pharmaceutical Industries a range of Filtering Face Pieces made with metal detectable plastic components!

Available as Fold Flat Design with or without exhalation valve! See below the table for more information and images of the range.

 

 

Features & Benefits of CK4002MD/CK4008MD

 

·  Inner layer is made of soft Polypropylene (P.P.), which reduces the fiber

    drops and increases the wearing comfort.

·  The filter layer is made of high efficient melt blown web, which resists dust  

    and oil-free particle.

·  Adjustable nosepiece provides a custom seal for different facial size.

·  Cool latex-free head strap for comfortable wearing.

    Complies EC type test requirement based on EN 149 : 2001 CE INSPEC

    Comfort Fold Flat style, light weight, and large surface area.
- Easy to store.
- Fits a wide range of face contours.
- Light weight provides greater work comfort, suits longer duration of wear.
- One way Metal Detectable Exhalation vent valve and Head Clips

- Promotes easy communication.


Suggested Industries & Application

·  Efficiently resist nuisance or organic acid vapours, suited to Food 

    Processing, Distillation and Breweries, chemical agriculture, solution

    cleaning, spray, printing, electronic, auto body shop, ship building, ink and

    dyeing, sterilizing, Drilling, Dyes & Dyestuffs, Ferrous & Non-ferrous

    Metallurgical industries, Fertilizer, Foundries, Glass Etching,

    Grinding, Leather Tanning, Paper processing,Paint & Pigments, Power 

    generation, Petrochemicals, Printing, Sand blasting, Sanding, Soldering,

    Textile, Tyre, Tobacco processing, etc.


Product Information :
- Weight :

- Breathing Resistance :Inhalation -
- Filtering efficiency :  Assigned protection factor -


Important information :
- See information supplied by manufacturer with product.
- Fitting instruction to be followed each time respirator in use.
- Failure to follow all use instructions and limitation on the use of this respirator

  and / or failure to wear this respirator during all times of exposure can reduce

  respirator effectiveness and result in sickness or death.
- Do not use for protection against Gases, Vapour, or in atmospheres

  containing less than 17 % oxygen.
- Use condition : Not against particles of Carcinogenic and Radioactive

  substances, micro-organisms (Viruses, Bacteria, and fungus) and Enzymes.

 

Colours Available:

 

- Colour : White / Blue Exhalation Valve and clips - yellow band

 

The CK range of disposable face masks is able to cater for most requirements, both personal choice and specifications for Health and Safety Regulations.

 

The CK range includes Moulded and Foldflat designs. Both with and without exhalation valves. The range is available with FFP1, FFP2 and FFP3 in various designs. We also have available Disposable nuisance dust masks
 

 Further Information

 

Substances in the atmosphere, dusts, fumes, vapours and gases and also micro-organisms encountered in the work place can cause damage to your health, in some cases even death.

 

This damage can occur by breathing in these substances.

Health and Safety Legislation requires employers to control exposure to these substances to protect their employees.

 

The first aim should always be to control the substance, so it is not in the atmosphere. However, this is not always possible and suitable personal protection must be provided.

This may include protective clothing and respirators.

 

Care is needed to choose the correct type of RPE (Respiratory Protective Equipment).

The RPE must be capable of providing a sufficient quantity of clean air for the wearer to breathe, the equipment must fit the wearer and the wearer must use it properly in accordance with the manufacturer instructions.

 

Please note that here is always a risk of leakage or contaminated air into RPE, no RPE can offer 100% protection.

 

Equipment such as face masks with filters and powered respirators, which take in contaminated air from the work room and filter/clean it before it is inhaled are all called Simple Filtering respirators.

Some respirators are designed to be disposable but can offer a great deal of protection. These respirators are called Disposable Filtering Face Pieces.

The following types of filter may be available:

 

1. For dusts and other particulate materials only

2. For certain gases and vapours only

3. Combination types for particulates and some gases and vapours

 

 

Fit Testing

 

IMPORTANT NOTICE

 

Fit Testing Of Respirators -  Training required

 

RPE Fit Testing is required for all tight-fitting face pieces including all filtering face pieces (disposable face masks), half masks and full-face masks. This includes negative pressure full-face masks as well as power-assisted full masks, and both self-contained and air-fed breathing apparatus.

 

Information Document HSE 282/28, recommends that RPE Fit Testing should only be conducted by a trained competent person.

 

The COSHH (Control of Substances Hazardous to Health) Regulations include a requirement that the initial selection process for all tight-fitting face pieces should include face-fit testing to ensure the wearer has a correctly fitting device. Face-Fit Testing is also required under the Control of Asbestos at Work Regulations and the Control of Lead at Work Regulations.

To be competent, the fit test operator should have adequate knowledge and have received adequate instruction and training in the following areas:

·         Regulations and Guidance

·         The Purpose and Applicability of Fit Testing

·         Procedures for Selection of Adequate and Suitable RPE

·         Fit Factors and Protection Factors

·         Examination Procedures for RPE, Identification of Maintenance Problems

·         Correct Donning Procedures and Pre-Use Fit Checks

·         Qualitative and Quantitative Face-Fit Testing

·         Sampling from the Face piece

·         Diagnostic Checks on Equipment

·         Correct Fit Testing Procedures, Purpose of the Fit Testing Exercises

·         Problem Solving

·         Capabilities and Limitations of the Fit Testing Equipment

·         Interpretation of Results

 

We are happy to advise our customers about how to find an accredited Respirator Face Fit Training course/or competent person to give you the skills and knowledge to meet the requirements of HSE282/28 for Competency of Fit Testing Operators.

 

For More Information Click Here

 

 

C K Safety Equipment Ltd  has 2 qualified fit testers who will be happy to assist you.

 

 

Non Toxic Dust Mask

CK4001

 

FFP1

CK 4006

 

FFP3

CK 4008

 

CK 4002MD

Designed for the Food /Beverage / Packaging and Processing Industry where contamination control is part of HACCP

 

 

Designed for the

CK 4008MD

 

 

Moldex Filtering Face Pieces

For Full range please contact sales@cksafety.com

 

 

CK 3205

 

 

CK 2405+

 

 

CK 2498

 

 

 

Further Information

Substances in the atmosphere, dusts, fumes, vapours and gases and also micro-organisms encountered in the work place can cause damage to your health, in some cases even death.

 

This damage can occur by breathing in these substances.

Health and Safety Legislation requires employers to control exposure to these substances to protect their employees.

 

The first aim should always be to control the substance, so it is not in the atmosphere. However, this is not always possible and suitable personal protection must be provided.

This may include protective clothing and respirators.

 

Care is needed to choose the correct type of RPE (Respiratory Protective Equipment).

The RPE must be capable of providing a sufficient quantity of clean air for the wearer to breathe, the equipment must fit the wearer and the wearer must use it properly in accordance with the manufacturer instructions.

 

Please note that here is always a risk of leakage or contaminated air into RPE, no RPE can offer 100% protection.

 

Equipment such as face masks with filters and powered respirators, which take in contaminated air from the work room and filter/clean it before it is inhaled are all called Simple Filtering respirators.

Some respirators are designed to be disposable but can offer a great deal of protection. These respirators are called Disposable Filtering Face Pieces.

The following types of filter may be available:

 

1. For dusts and other particulate materials only

2. For certain gases and vapours only

3. Combination types for particulates and some gases and vapours

 

 

Fit Testing

 

IMPORTANT NOTICE

 

Fit Testing Of Respirators -  Training required

 

RPE Fit Testing is required for all tight-fitting face pieces including all filtering face pieces (disposable face masks), half masks and full-face masks. This includes negative pressure full-face masks as well as power-assisted full masks, and both self-contained and air-fed breathing apparatus.

 

Information Document HSE 282/28, recommends that RPE Fit Testing should only be conducted by a trained competent person.

 

The COSHH (Control of Substances Hazardous to Health) Regulations include a requirement that the initial selection process for all tight-fitting face pieces should include face-fit testing to ensure the wearer has a correctly fitting device. Face-Fit Testing is also required under the Control of Asbestos at Work Regulations and the Control of Lead at Work Regulations.

To be competent, the fit test operator should have adequate knowledge and have received adequate instruction and training in the following areas:

·         Regulations and Guidance

·         The Purpose and Applicability of Fit Testing

·         Procedures for Selection of Adequate and Suitable RPE

·         Fit Factors and Protection Factors

·         Examination Procedures for RPE, Identification of Maintenance Problems

·         Correct Donning Procedures and Pre-Use Fit Checks

·         Qualitative and Quantitative Face-Fit Testing

·         Sampling from the Face piece

·         Diagnostic Checks on Equipment

·         Correct Fit Testing Procedures, Purpose of the Fit Testing Exercises

·         Problem Solving

·         Capabilities and Limitations of the Fit Testing Equipment

·         Interpretation of Results

 

We are happy to advise our customers about how to find an accredited Respirator Face Fit Training course/or competent person to give you the skills and knowledge to meet the requirements of HSE282/28 for Competency of Fit Testing Operators.

 

For More Information Click Here

 

Code

Detectable Filtering Face Pieces

CK4002MD Filtering face piece/toxic dusts  FFP2 (also available as Metal Detectable)
CK4008MD Filtering face piece/toxic dusts c/w valve  FFP2 (also available as Metal Detectable

 

Code Dust Masks
  Non Toxic Nuisance Dust Mask
CK4001 Filtering face piece / non toxic nuisance dust
  Standard Filtering Face Pieces
CK4003 Filtering face piece/toxic dusts & nuisance odours FFP1
CK4004 Filtering face piece/toxic dusts FFP1
CK4006 Filtering face piece/toxic dusts c/w valve FFP1
CK4007 Filtering face piece/fold flat FFP1 (S)
CK4002 Filtering face piece/toxic dusts FFP2
CK4008 Filtering face piece/toxic dusts c/w valve FFP3
 

Detectable Filtering Face Pieces and blue masks/parts for visual detection by the Food /Beverage / Packaging and Processing Industry where contamination control is part of HACCP

CK4002 Filtering face piece/toxic dusts  FFP2
CK4008 Filtering face piece/toxic dusts c/w valve  FFP2
CK2405+ Filtering face piece/toxic dusts/ blue moulded with valve FFP2
CK2498 Filtering face piece/ toxic dusts/ blue harness with valve FFP2
CK3205

Filtering face piece/toxic dusts/ blue clip with valve FFP3

 

Respiratory Protection (Particulates)

 

In order for a mask to be used as a protective device it must be tested to EN149

A summary of the protection levels available are summarized below.

 

Type (EN149:2001)

Protection Against

Wel*

Workplace Exposure Level

 

FFP1

 

Non toxic dusts, mists and fumes based on water and not oil. NOT to be used against cancer causing radioactive substances and air transmitted biological substances including enzymes

 

4

 

FFP2

 

Toxic dusts, mists and fumes based on water and oil

 

10

 

FFP3

 

Against all dusts, mists and fumes based on water and oil

 

20

 

D

 

When quoted (e.g FFP2D) this indicated that the mask has passed the optional Dolomite clogging test.

Meaning the mask will generally last longer before the filter media becomes clogged)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Patented

 

 

 

 

 

 

 

© 2009 CK European Safety

home  ::  free advice  ::  vinyl detecta glove  ::  respirators  ::  face masks  ::  ear protection  ::  links  ::  product range  ::  contact us  ::  site map