C K Safety Equipment can now
exclusively provide its customers in
the Food /Beverage and Pharmaceutical
Industries a range of Filtering Face
Pieces made with metal detectable
plastic components!
Available as Fold Flat Design with or
without exhalation valve! See below the
table for more information and images of
the range.
Features & Benefits of CK4002MD/CK4008MD
·
Inner layer is made of soft
Polypropylene (P.P.), which reduces the
fiber
drops and increases the wearing
comfort.
·
The filter layer is made of high
efficient melt blown web, which resists
dust
and oil-free particle.
·
Adjustable nosepiece provides a custom
seal for different facial size.
·
Cool latex-free head strap for
comfortable wearing.
Complies EC type test requirement based
on EN 149 : 2001 CE INSPEC
Comfort Fold Flat style, light weight,
and large surface area.
- Easy to store.
- Fits a wide range of face contours.
- Light weight provides greater work
comfort, suits longer duration of wear.
- One way Metal
Detectable Exhalation vent valve and
Head Clips
- Promotes easy communication.
Suggested Industries & Application
·
Efficiently resist nuisance or organic
acid vapours, suited to Food
Processing,
Distillation and Breweries, chemical
agriculture, solution
cleaning, spray,
printing, electronic, auto body shop,
ship building, ink and
dyeing,
sterilizing, Drilling, Dyes & Dyestuffs,
Ferrous & Non-ferrous
Metallurgical
industries, Fertilizer, Foundries, Glass
Etching,
Grinding, Leather Tanning, Paper
processing,Paint & Pigments, Power
generation,
Petrochemicals, Printing, Sand blasting,
Sanding,
Soldering,
Textile, Tyre, Tobacco
processing, etc.
Product Information :
- Weight :
- Breathing Resistance :Inhalation -
- Filtering efficiency :
Assigned protection factor -
Important information :
- See information supplied by
manufacturer with product.
- Fitting instruction to be followed
each time respirator in use.
- Failure to follow all use instructions
and limitation on the use of this
respirator
and / or failure to wear this
respirator during all times of exposure
can reduce
respirator effectiveness and
result in sickness or death.
- Do not use for protection against
Gases, Vapour, or in atmospheres
containing less than 17 % oxygen.
- Use condition : Not against particles
of Carcinogenic and Radioactive
substances, micro-organisms (Viruses,
Bacteria, and fungus) and Enzymes.
Colours Available:
- Colour : White / Blue Exhalation Valve
and clips - yellow band
The CK range of disposable face masks is
able to cater for most requirements,
both personal choice and specifications
for Health and Safety Regulations.
The CK range includes Moulded and
Foldflat designs. Both with and without
exhalation valves.
The range is available with FFP1, FFP2
and FFP3 in various designs.
We also have available Disposable
nuisance dust masks
Further
Information
Substances in the atmosphere, dusts,
fumes, vapours and gases and also
micro-organisms encountered in the work
place can cause damage to your health,
in some cases even death.
This damage can occur by breathing in
these substances.
Health and Safety Legislation requires
employers to control exposure to these
substances to protect their employees.
The first aim should always be to
control the substance, so it is not in
the atmosphere. However, this is not
always possible and suitable personal
protection must be provided.
This may include protective clothing and
respirators.
Care is needed to choose the correct
type of RPE (Respiratory Protective
Equipment).
The RPE must be capable of providing a
sufficient quantity of clean air for the
wearer to breathe, the equipment must
fit the wearer and the wearer must use
it properly in accordance with the
manufacturer instructions.
Please note that here is always a risk
of leakage or contaminated air into RPE,
no RPE can offer 100% protection.
Equipment such as face masks with
filters and powered respirators, which
take in contaminated air from the work
room and filter/clean it before it is
inhaled are all called
Simple Filtering respirators.
Some respirators are designed to be
disposable but can offer a great deal of
protection. These respirators are called
Disposable Filtering Face Pieces.
The following types of filter may be
available:
1. For dusts and other particulate
materials only
2. For certain gases and vapours only
3. Combination types for particulates
and some gases and vapours
Fit Testing
IMPORTANT NOTICE
Fit Testing Of Respirators - Training
required
RPE Fit Testing is required for all tight-fitting face pieces
including all filtering face pieces
(disposable face masks), half masks and
full-face masks. This includes negative
pressure full-face masks as well as
power-assisted full masks, and both
self-contained and air-fed breathing
apparatus.
Information Document HSE 282/28, recommends that RPE Fit Testing
should only be conducted by a
trained competent person.
The
COSHH (Control of
Substances Hazardous to Health)
Regulations include a requirement that
the initial selection process for all
tight-fitting face pieces should include
face-fit testing to ensure the wearer
has a correctly fitting device.
Face-Fit Testing is also
required under the Control of Asbestos
at Work Regulations and the Control of
Lead at Work Regulations.
To be competent, the fit test operator should have adequate
knowledge and have received adequate
instruction and training in the
following areas:
·
Regulations and Guidance
·
The Purpose and Applicability of Fit Testing
·
Procedures for Selection of Adequate and Suitable RPE
·
Fit Factors and Protection Factors
·
Examination Procedures for RPE, Identification of Maintenance
Problems
·
Correct Donning Procedures and Pre-Use Fit Checks
·
Qualitative and Quantitative Face-Fit Testing
·
Sampling from the Face piece
·
Diagnostic Checks on Equipment
·
Correct Fit Testing Procedures, Purpose of the Fit Testing
Exercises
·
Problem Solving
·
Capabilities and Limitations of the Fit Testing Equipment
·
Interpretation of Results
We are happy to advise our customers about how to find an
accredited Respirator Face Fit Training
course/or competent person to give
you the skills and knowledge to meet the
requirements of HSE282/28 for Competency
of Fit Testing Operators.
For More
Information Click Here
C K Safety Equipment Ltd has
2 qualified fit testers who will be
happy to assist you.

Non Toxic Dust Mask
CK4001

FFP1
CK 4006

FFP3
CK 4008

CK 4002MD
Designed for the Food /Beverage /
Packaging and Processing Industry where
contamination control is part of HACCP

Designed for the
CK 4008MD

Moldex Filtering Face Pieces
For Full range please contact
sales@cksafety.com

CK 3205

CK 2405+

CK 2498
Further Information
Substances in the atmosphere, dusts,
fumes, vapours and gases and also
micro-organisms encountered in the work
place can cause damage to your health,
in some cases even death.
This damage can occur by breathing in
these substances.
Health and Safety Legislation requires
employers to control exposure to these
substances to protect their employees.
The first aim should always be to
control the substance, so it is not in
the atmosphere. However, this is not
always possible and suitable personal
protection must be provided.
This may include protective clothing and
respirators.
Care is needed to choose the correct
type of RPE (Respiratory Protective
Equipment).
The RPE must be capable of providing a
sufficient quantity of clean air for the
wearer to breathe, the equipment must
fit the wearer and the wearer must use
it properly in accordance with the
manufacturer instructions.
Please note that here is always a risk
of leakage or contaminated air into RPE,
no RPE can offer 100% protection.
Equipment such as face masks with
filters and powered respirators, which
take in contaminated air from the work
room and filter/clean it before it is
inhaled are all called
Simple Filtering respirators.
Some respirators are designed to be
disposable but can offer a great deal of
protection. These respirators are called
Disposable Filtering Face Pieces.
The following types of filter may be
available:
1. For dusts and other particulate
materials only
2. For certain gases and vapours only
3. Combination types for particulates
and some gases and vapours
Fit Testing
IMPORTANT NOTICE
Fit Testing Of Respirators - Training
required
RPE Fit Testing is required for all
tight-fitting face pieces including all
filtering face pieces (disposable face
masks), half masks and full-face masks.
This includes negative pressure
full-face masks as well as
power-assisted full masks, and both
self-contained and air-fed breathing
apparatus.
Information Document HSE 282/28,
recommends that RPE Fit Testing should
only be conducted by a
trained competent person.
The
COSHH (Control of
Substances Hazardous to Health)
Regulations include a requirement that
the initial selection process for all
tight-fitting face pieces should include
face-fit testing to ensure the wearer
has a correctly fitting device.
Face-Fit Testing is also
required under the Control of Asbestos
at Work Regulations and the Control of
Lead at Work Regulations.
To be competent, the fit test operator
should have adequate knowledge and have
received adequate instruction and
training in the following areas:
·
Regulations and Guidance
·
The Purpose and Applicability of Fit
Testing
·
Procedures for Selection of Adequate and
Suitable RPE
·
Fit Factors and Protection Factors
·
Examination Procedures for RPE,
Identification of Maintenance Problems
·
Correct Donning Procedures and Pre-Use
Fit Checks
·
Qualitative and Quantitative Face-Fit
Testing
·
Sampling from the Face piece
·
Diagnostic Checks on Equipment
·
Correct Fit Testing Procedures, Purpose
of the Fit Testing Exercises
·
Problem Solving
·
Capabilities and Limitations of the Fit
Testing Equipment
·
Interpretation of Results
We are happy to advise our customers
about how to find an accredited
Respirator Face Fit Training course/or
competent person to give you the skills
and knowledge to meet the requirements
of HSE282/28 for Competency of Fit
Testing Operators.
For More
Information Click Here
|
Code |
Detectable Filtering Face Pieces |
|
CK4002MD |
Filtering face piece/toxic dusts FFP2 (also available as Metal
Detectable) |
|
CK4008MD |
Filtering face piece/toxic dusts c/w valve FFP2 (also
available as Metal Detectable |
|
Code |
Dust Masks |
|
|
Non Toxic Nuisance Dust Mask |
|
CK4001 |
Filtering face piece / non toxic
nuisance dust |
|
|
Standard Filtering Face Pieces |
|
CK4003 |
Filtering face piece/toxic dusts
& nuisance odours FFP1 |
|
CK4004 |
Filtering face piece/toxic dusts
FFP1 |
|
CK4006 |
Filtering face piece/toxic dusts
c/w valve FFP1 |
|
CK4007 |
Filtering face piece/fold flat
FFP1 (S) |
|
CK4002 |
Filtering face piece/toxic dusts
FFP2 |
|
CK4008 |
Filtering face piece/toxic dusts
c/w valve FFP3 |
|
|
Detectable Filtering Face Pieces
and blue masks/parts for visual
detection by the
Food /Beverage /
Packaging and Processing
Industry where contamination
control is part of HACCP |
|
CK4002 |
Filtering face piece/toxic dusts
FFP2 |
|
CK4008 |
Filtering face piece/toxic dusts
c/w valve FFP2 |
|
CK2405+ |
Filtering face
piece/toxic dusts/ blue moulded
with valve FFP2 |
|
CK2498 |
Filtering face
piece/ toxic dusts/ blue harness
with valve FFP2 |
|
CK3205 |
Filtering face piece/toxic
dusts/ blue clip with valve FFP3 |
Respiratory Protection (Particulates)
In order for a mask to be used as a
protective device it must be tested to
EN149
A summary of the protection levels
available are summarized below.
|
Type
(EN149:2001) |
Protection
Against |
Wel*
Workplace
Exposure Level |
|
FFP1 |
Non toxic
dusts, mists and fumes based on
water and not oil. NOT to be
used against cancer causing
radioactive substances and air
transmitted biological
substances including enzymes |
4 |
|
FFP2 |
Toxic dusts,
mists and fumes based on water
and oil |
10 |
|
FFP3 |
Against all
dusts, mists and fumes based on
water and oil |
20 |
|
D |
When quoted (e.g
FFP2D) this indicated that the
mask has passed the optional
Dolomite clogging test.
Meaning the
mask will generally last longer
before the filter media becomes
clogged) |
|